Annals of African Medicine
Home About AAM Editorial board Ahead of print Current Issue Archives Instructions Subscribe Contact us Search Login 
ORIGINAL ARTICLE
Year : 2022  |  Volume : 21  |  Issue : 1  |  Page : 49-53

Accuracy of ultrasound estimation of fetal weight at term: A comparison of shepard and hadlock methods


Department of Obstetrics and Gynecology, University of Abuja Teaching Hospital, Abuja FCT, Nigeria

Correspondence Address:
Nathaniel David Adewole
Department of Obstetrics and Gynecology, University of Abuja Teaching Hospital, Abuja-FCT
Nigeria
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/aam.aam_76_20

Rights and Permissions

Background: Ultrasound measurement provides a noninvasive means of obtaining information about fetal weight and may help in necessary preparations at and after delivery. Although some ultrasound methods include only one or two fetal indices, others, to improve accuracy, incorporate either three or all the four fetal indices. The aim of this report is to assess the accuracy of two different methods for fetal weight estimation. Materials and Methods: This was a prospective study of 170 consecutive pregnant women at term. Ultrasound was used to estimate fetal weight by the Shepard and Hadlock methods, and the actual birth weight (ABW) was determined at birth. The ultrasound-estimated fetal weights (EFWs) and ABW were analyzed. Results: The women were aged 21–42 years (mean 31.3 ± 7 years). The EFW using the Shepard method was 1.9 kg–5.0 kg (mean 3.6 ± 0.5 kg) and 1.8 kg–4.4 kg (mean 3.3 ± 0.4 kg) for Hadlock method, and ABW was 2.0 kg–4.5 kg (mean 3.4 ± 0.5 kg). The mean EFW using the Shepard method was significantly higher than that of ABW (P < 0.001). The Shepard method significantly overestimated macrosomia compared to that by the ABW. There was no significant difference in microsomia rate between the two methods and ABW. Conclusion: The Hadlock method was more accurate at estimating fetal weight compared to the Shepard method and is recommended for the ultrasound estimation of fetal weight in our setting and similar settings.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1900    
    Printed54    
    Emailed0    
    PDF Downloaded7    
    Comments [Add]    

Recommend this journal